EasyManua.ls Logo

Diamond DA 62 - Page 165

Diamond DA 62
506 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Normal Operating
Procedures
DA 62 AFM
Below instrument panel in front of right seat:
a) ALTERNATE AIR. . . . . . . . . . . . . . . . . . . . . . check CLOSED
On the instrument panel:
a) ALTERNATOR. . . . . . . . . . . . . . . . . . . . . . . . check both ON
b) VOTER switch . . . . . . . . . . . . . . . . . . . . . . . . check both AUTO
c) PITOT HEAT . . . . . . . . . . . . . . . . . . . . . . . . . check OFF
d) ENGINE MASTER . . . . . . . . . . . . . . . . . . . . . check both OFF
e) AVIONIC MASTER . . . . . . . . . . . . . . . . . . . . check OFF
f) GEAR SELECTOR . . . . . . . . . . . . . . . . . . . . check DOWN
g) FLAP SELECTOR . . . . . . . . . . . . . . . . . . . . . check UP
h) Circuit breakers . . . . . . . . . . . . . . . . . . . . . . . set in (if one has been pulled, check
reason)
i) All electrical equipment . . . . . . . . . . . . . . . . . OFF
j) ELT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . armed
Check procedure:
a) ELECT. MASTER . . . . . . . . . . . . . . . . . . . . . ON
CAUTION
When switching the ELECT. MASTER ON, the electrically
driven hydraulic gear pump may activate itself for 5 to 20
seconds in order to restore the system pressure. Should the
pump continue to operate continuously or periodically,
terminate flight. There is a malfunction in the landing gear
system.
CONTINUED
Page 4A - 8 Rev. 0 11-Jan-2019 Doc. No. 11.01.05-E