DA 62 AFM
Normal Operating
Procedures
CAUTION
Do not overheat the starter motor. Do not operate the starter
motor for more than 10 seconds.
At ambient temperatures below -22°C, it is possible that the
engine will not start at the first attempt. In this case, wait
60 seconds between the start attempts.
If the "L STARTER" annunciation comes on after the engine
has started and the START push button has been released,
set the ENGINE MASTER to OFF and investigate the
problem.
6. Annunciations/Engine/System Page . . . . . . . check OK/normal range
7. Annunciations/Starter . . . . . . . . . . . . . . . . . . check OFF
8. Annunciations/Oil pressure . . . . . . . . . . . . . . check OK
WARNING
If the oil pressure has not moved from the red range within
3 seconds after starting, set the ENGINE MASTER switch
to OFF and investigate problem.
9. Circuit breakers . . . . . . . . . . . . . . . . . . . . . . . check all in/as required
10. Idle RPM . . . . . . . . . . . . . . . . . . . . . . . . . . . . check, 710 ± 30 RPM
Repeat with opposite engine.
END OF CHECKLIST
Doc. No. 11.01.05-E Rev. 0 11-Jan-2019 Page 4A - 23