Abnormal Operating
Procedures
DA 62 AFM
CAUTION
Do not overheat the starter motor. Do not operate the starter
motor for more than 10 seconds.
At ambient temperatures below -20°C it is possible that the
engine will not run at the first attempt. In this case, wait 60
seconds between the start attempts.
If the L/R STARTER annunciation does not extinguish after
the engine has started and the START button has been
released, set the ENGINE MASTER to OFF and investigate
the problem.
8. Annunciations/Engine/System Page . . . . . . . check OK/normal range
9. Annunciations/Starter. . . . . . . . . . . . . . . . . . . check OFF
10. Annunciations/Oil pressure . . . . . . . . . . . . . . check OK
WARNING
If the oil pressure has not moved from the red range within
3 seconds after starting, set the ENGINE MASTER switch
to OFF and investigate problem.
11. Circuit breakers . . . . . . . . . . . . . . . . . . . . . . . check all in/as required
12. Idle RPM . . . . . . . . . . . . . . . . . . . . . . . . . . . . check, 710 ± 30 RPM
13. External power . . . . . . . . . . . . . . . . . . . . . . . . disconnect
14. RH engine . . . . . . . . . . . . . . . . . . . . . . . . . . . start with normal procedure
END OF CHECKLIST
Page 4B - 34 Rev. 0 11-Jan-2019 Doc. No. 11.01.05-E