Operating Limitations DA 62 AFM
h) Oil temperature
Minimum : -30 °C (-22 °F)
Maximum : 139 °C (282 °F)
Normal range : 50 °C - 135 °C (122 °F - 275 °F)
i) Gearbox temperature
Minimum : -30 °C (-22 ° F)
Minimum (full load) : 35 °C (95 °F)
Maximum : 120 °C (248 °F)
NOTE
A cautionary (yellow) gearbox temperature range is not
imposed by the engine manufacturer. However, there is a
delay between power changes and gearbox temperature.
Therefore, a cautionary range has been added to the G1000
gearbox temperature instrument solely to make the pilot
attentive to the gearbox temperature approaching the
maximum allowable limit. There is no specific time limit
associated with operating in the cautionary gearbox
temperature range.
j) Coolant temperature
Minimum (at start-up) : -30 °C (-22 °F)
Minimum (full load) : 60 °C (140 °F)
Maximum : 100 °C (212 °F)
Page 2 - 8 Rev. 0 11-Jan-2019
DOT
approved
Doc. No. 11.01.05-E