490
b. Set the mode that will be used to run the capture filter:
(config network analyzer name)> when mode
(config network analyzer name)>
where mode is one of the following:
n
boot: The script will run once each time the device boots.
n
interval: The script will start running at the specified interval, within 30 seconds
after the configuration change is saved. If interval is selected, set the interval:
(config add network analyzer name)> on_interval value
(config add network analyzer name)>
where value is any number of weeks, days, hours, minutes, or seconds, and takes
the format number{w|d|h|m|s}.
For example, to set on_interval to ten minutes, enter either 10m or 600s:
(config network analyzer name)> on_interval 600s
(config network analyzer name)>
n
set_time: Runs the script at a specified time of the day. If set_time is set, set the
time that the script should run, using the format HH:MM:
(config network analyzer name)> run_time HH:MM
(config network analyzer name)>
n
maintenance_time: The script will run during the system maintenance time
window.
c. Set the amount of time that the scheduled analyzer session will run:
(config network analyzer name)> duration value
(config network analyzer name)>
where value is any number of weeks, days, hours, minutes, or seconds, and takes the
format number{w|d|h|m|s}.
For example, to set duration to ten minutes, enter either 10m or 600s:
(config network analyzer name)> save_interval 600s
(config network analyzer name)>
d. Set the frequency with which captured events will be saved:
(config network analyzer name)> save_interval value
(config network analyzer name)>
where value is any number of weeks, days, hours, minutes, or seconds, and takes the
format number{w|d|h|m|s}.
For example, to set save_interval to ten minutes, enter either 10m or 600s: