DISPLAY MESSAGES AND FAULT FINDING
4-6 25257 Issue 3 November 2013
Control Process Messages
No. Error Text Description
5060 Too much trigger outputs Message category: Warning
Remedial action: Check trigger output
configuration in Group setup
5061 Trigger output buffer
overrun
Message category: Warning
Remedial action: Check trigger output
configuration in Group setup
5062 Trigger output pulse
overlaps
Message category: Warning
Remedial action: Check trigger output
configuration in Group setup
5070 Too much image ready
outputs
Message category: Warning
Remedial action: Check print image
ready output configuration
5100 No D-Top, Printgroup n Message category: Warning
Remedial action: Check print-start
mode in message definition or D-Top
input configuration
5101 Multiple D-Top,
Printgroup n
Message category: Warning
Remedial action: Check photocell
setup or length of printed message
5102 Second D-Top while no
encoder, n
Message category: Warning
Remedial action: Check photocell
setup
6001 Unknown SB0 in BDT
task
Internal communication
Error list: System error message
Message category: Alarm
Remedial action: Restart control
6002 Unknown SB1 at
SB0_INIT
Internal communication
Error list: System error message
Message category: Alarm
Remedial action: Restart control
6003 Unknown SB1 at
SB0_EXCEPTION
Internal communication
Error list: System error message
Message category: Alarm
Remedial action: Restart control