DISPLAY MESSAGES AND FAULT FINDING
25257 Issue 3 November 2013 4-17
Cyclic Operation Messages
No. Error Text Description
6200 Barcode n: error n (1-18) Message category: Alarm
Remedial action: Correct barcode
format
Firmware Error code & Description
0 = No error
1 = Invalid parameter / unsupported value
2 = Wrong character / invalid data
3 = Wrong number of input characters
4 = Invalid number of input characters in
combination with Composite
5 = Input string too long
6 = Barcode does not fit into bounding
rectangle
7 = No barcode data
8 = Not supported
9 = Method or barcode type not
implemented
10 = Unexpected error
11 = Out of memory
12 = Wrong check digit
13 = Quiet zone too small for vertical
bearer bars
14 = Invalid character for hexadecimal digit
15 = External library is missing
16 = BCCreate must be called before
17 = Invalid or missing code page or invalid
characters
18 = Invalid data format. Please examine the
specification.
7001 Unknown SB0 during
news interpretation in zyk
task
Internal communication
Error list: System error message
Message category: Alarm
Remedial action: Restart control
7002 Unknown SB1 at
SB0_INIT
Internal communication
Error list: System error message
Message category: Alarm
Remedial action: Restart control
7003 Unknown SB1 at
SB0_EXCEPTION
Internal communication
Error list: System error message
Message category: Alarm
Remedial action: Restart control