OPERATION
25257 Issue 3 November 2013 3-45
COUNTER CONFIGURATION
Select Service>Config>Counters:
Counter: Name can be given to counter. This name will be used when
programming messages using this counter.
Type incr-source: Select the type of source to be used to increment the
value of the counter:
• No increment source: Counter is not activated in the machine.
• Digital input: Counter increments each time the digital input is
activated.
• After each message group: Counter increments after each message is
printed.
• After each element of message group: when using the repeat print
feature (i.e. one print start = several prints or “elements” in the same
message) the counter is incremented after each printing of the element
• Counter overrun: Incrementation of this counter will be linked to the
overrun of another counter.
Incr-source: Defines the source of incrementation based on the source type
selected above. If the type of incremental source is:
• Digital input: Select the input number.
• After each message group: Select the group on which the message is
loaded.
• After each element of message group: Select the group on which
the message is loaded.
• Counter overrun: Select the counter to which it will be linked.
Type reset-source: Counter can be reset externally using the following
methods:
• No reset source: No external counter reset.
• After each message group: After the print of a message the counter is
reset.