OPERATION
25257 Issue 3 November 2013 3-33
If it has been set to make it mandatory to enter
a value in one or more variables in a message
and this has not been done then a warning will
be displayed when you attempt to put that
message online:
(2) Using the Automatic Variable
Prompt:
(a) Navigate to Service | Config | Assign Group.
(b) Enable the Automatic Variable Prompt by setting “Variable text
window” to “Yes”.
Once it is enabled the user will be prompted, when attempting to set the
message to print, to enter variable data in the vtext elements of a message:
(c) If multiple variable elements are displayed, use the Up/Down
arrows to select the element required.
(d) Press the “Edit” button and use the keyboard to enter the relevant
alpha/numeric data.
An “M” to the right of a variable
indicates that it has been set so it is
compulsory to enter data in that variable.
If no data is entered the message cannot
be set to print and a warning message
will be displayed.
Note: Variable text can be updated both internally, as described above, through
the Production menu and externally through a PC application using the
protocols provided.