EasyManua.ls Logo

DURKOPP ADLER 513 - 4.12 Performing a Manual Test Run

DURKOPP ADLER 513
130 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Programming
Operating Instructions 513/533 - 01.0 - 09/2023 65
Fig. 49: Set button sewing function (for 533) (2)
7. Use the buttons to set the value to 7.
8. To save the settings, press the button.
The settings are saved and the message appears that
machining is in progress and the machine must NOT be
switched off.
After a short time the message appears that the machine
can be switched off
9. Switch off the machine.
10. Switch machine on again.
The button sewing function is now active and the machine is
ready for sewing.
4.12 Performing a manual test run
To check if the selected standard seam pattern matches
the installed clamp, you can perform a manual test run.
To perform a manual test run:
1. Press the button.
2. Select the desired standard seam pattern using the
buttons.
3. Press the button.
4. Press the button.
The machine enters the manual test run mode.