4.1.3 Timing the operation of the switches
Rule and control
The switches S3, S6 and S8 should be operated short before the end
position of the outer frame.
When switching on, hold the key "
F3
" pressed down.
Select the function "
Checking the input elements
".
Move the outer frame by hand.
The display will show the circuit state of the input element, the
state of which has changed.
Check whether the following switches are releasing:
S3 outer frame, rear
S6 outer frame, top
S8 outer frame, bottom
Correction
Loosen the clamping screw of the switch to be changed.
Change the position of the switch.
Tighten the clamping screw of the switch.
S3
S6
S8
69