4. Verify MANIFOLD (HIGH FIRE) GAS PRESSURE.
a. Using a short straight-line slotted screwdriver, loosen the slotted brass at head screw with
approximately two counter-clockwise turns on the MANIFOLD PRESSURE TAP (5) (Figure 2-115)
located on the underside of the gas valve.
b. Mount you manometer tube on the MANIFOLD PRESSURE TAP (5) (Figure 2-116).
c. Start the oven (Figure 2-117) and record pressure prior once the MAIN BLOWER FAN has begun
spinning, this should be conducted within 15 seconds of powering the oven on. (Figure 2-118)
d. Record the pressure reading once the oven has red (Figure 2-119) and subtract the previous pressure
reading from it. This will give the true manifold pressure. See the “MANIFOLD ADJUSTMENT” section
for a detailed explanation of how to adjust the manifold pressure and an example of how to calculate
true manifold pressure.
e. Required gas pressure setting can be located on the oven data decal, located on the control cabinet
side. See “” in the following section. (Example Figure 2-120)
5. Conduct leak checks of all oven supply pipework and internal gas components.
FINAL CONNECTIONS
GAS CONNECTION (CONTINUED)
FIGURE 2-115 FIGURE 2-116
FIGURE 2-120
FIGURE 2-117
FIGURE 2-118 FIGURE 2-119