EasyManua.ls Logo

Eickemeyer MAGIC 6000 - User Manual

Eickemeyer MAGIC 6000
216 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
USER MANUAL
TELEFON +49 7461 96580 0
www.eickemeyer.com
Art. No. 303720
MAGIC 6000
ULTRASOUND UNIT

Table of Contents

Questions and Answers

  • K
    Kiara LynchAug 2, 2025
    How to improve degraded image quality on Eickemeyer Medical Equipment?
    • T
      Tonya VelasquezAug 2, 2025
      To improve degraded image quality, ensure you have selected the correct exam type. Adjust the image settings via post-processing, or reset the post-processing to the default values. You can also reset the system to the factory default setups.
  • J
    John JonesAug 9, 2025
    What to do if Eickemeyer MAGIC 6000 monitor displays characters but no images?
    • B
      Brendan Wiley IVAug 9, 2025
      If your monitor displays characters but no images, adjust the transmission power, gain, or TGC control. Also, ensure that the probe is properly and fully connected. Finally, check if the system is in a frozen state and unfreeze the image.
  • S
    Stacie PriceAug 14, 2025
    Why is the button on my Eickemeyer MAGIC 6000 Medical Equipment unresponsive and buzzing?
    • M
      Michael DeleonAug 14, 2025
      The button may be unresponsive because it is blocked by dirt. Check the control panel for any blockage and press the button several times to release it. Clean the button to ensure it functions correctly.
  • R
    Rachel AlvaradoAug 20, 2025
    What to do if the power indicator is on but the Eickemeyer Medical Equipment image is blank?
    • K
      Kayla ReynoldsAug 21, 2025
      If the power indicator is on but the image is blank, turn off the system and wait at least one minute before restarting it. Also, adjust the contrast settings on the monitor.
  • M
    Mr. Dillon OdonnellAug 27, 2025
    How to fix a power indicator that doesn't light up on Eickemeyer Medical Equipment?
    • V
      Vincent MelendezAug 27, 2025
      If the power indicator doesn't light up after turning on the power supply, verify that the plug is securely connected and has not become loosened or dislodged from the back of the system.

Summary

Safety Precautions

Safety Classification

Classifies equipment based on protection against electric shock and water ingress.

Signal Word Meanings

Explains the meanings of DANGER, WARNING, CAUTION, NOTE, and Tips.

General Safety Precautions

Details electrical safety, flammability, water exposure, and transducer handling.

Warning Labels

Describes the meaning and significance of various warning labels on the system.

System Overview

Intended Use and Contraindications

Specifies the system's application scope and any restrictions.

System Configuration and Probes

Details standard configuration, available probes, and their intended uses.

Unit Introduction and Symbols

Identifies main system components and explains interface symbols.

System Preparation

Moving and Positioning the System

Instructions for safe placement, including space requirements.

Power Supply Options

Details connecting to external power or using the internal battery.

Powering ON and OFF Procedures

Guides on safe system startup, shutdown, and standby modes.

Probe Connection and Disconnection

Step-by-step guide for attaching and detaching ultrasound probes.

Exam Preparation

Starting an Exam

Outlines the initial steps to begin a new animal examination.

Animal Information Management

Covers entering, retrieving, and managing patient data.

Selecting Exam Mode and Probe

Guide to choosing the appropriate settings for an examination.

Image Optimization

Switching Image Modes

How to navigate between B Mode, M Mode, and split-screen display.

B Mode Optimization

Details parameters specific to B-mode image enhancement.

M Mode Optimization

Explains M-mode specific image adjustments and parameters.

Image Presets

How to set and use predefined image parameter configurations.

Display & Cine Review

Image Display Modes

Explains split-screen display and image magnification features.

Cine Review Functionality

Guides on reviewing captured images and loops, including manual and auto modes.

Measurement

Basic Measurement Operations

Instructions for entering and exiting measurement modes.

General Measurements

Details available measurement tools for 2D and M Mode scans.

Measurement Accuracy Specifications

Provides accuracy data and tolerances for various measurements.

Comments and Body Marks

Adding and Managing Comments

Procedures for entering, editing, and displaying text annotations on images.

Using Body Marks

How to indicate anatomical position and orientation with pictograms.

Data Management

Animal Information Management

Covers data entry, storage, and display settings for animal information.

Image File Management

Details file formats, storage media, and saving presets for images.

iStation Data Management

Operations within the iStation patient data system for searching and viewing.

Access Control and System Login

Describes user roles, permissions, and login procedures.

DICOM

DICOM Presets Configuration

Configuration for network settings and DICOM service properties.

DICOM Services Operations

Details on sending images via DICOM Storage, Print, and Worklist.

Setup

System Preset Configuration

Settings for hospital name, language, date/time, and other system parameters.

Exam Presets

Customizing exam modes, probes, and associated settings.

Manage Settings (Export;Import)

Procedures for backing up and restoring system configuration data.

System Information

Viewing product, hardware, software, and option module details.

Probes and Biopsy

Probe Overview and Transducer Parts

Lists available probes and identifies key transducer components.

Biopsy Guide Procedures

Explains the process, precautions, and safety for ultrasound-guided biopsy.

Needle-guided Brackets

Details components, installation, and cleaning of biopsy guide brackets.

Battery

Battery Overview and Precautions

General information and safety guidelines for system battery usage.

Battery Installation and Removal

Steps for safely installing and removing the system battery.

Battery Status and Performance

How to check battery level, capacity, and performance.

Acoustic Output

Bioeffects and Prudent Use

Information on ultrasound safety, responsible usage, and ALARA principle.

MI;TI Explanation and Display

Understanding Mechanical Index (MI) and Thermal Index (TI) values.

Acoustic Power Settings and Control

Adjusting ultrasound output levels and controlling image quality.

Acoustic Output Parameters and Limits

Technical data on output levels, attenuation, and regulatory limits.

Guidance and Manufacturer’s Declaration

Electromagnetic Emissions Guidance

Information on system compliance with EMC emission standards.

Electromagnetic Immunity Guidance

Details on system immunity to electrical interference and RF fields.

System Maintenance

Daily Maintenance Procedures

Steps for routine cleaning of the system, probes, and accessories.

Maintenance Checks by Service Engineer

Tasks performed by authorized personnel for safety and performance.

Troubleshooting Common Issues

Guidance for resolving common system malfunctions and errors.

Appendix A Transducer Maximum Surface Temperature

Transducer Temperature Test Results

Presents test data for transducer surface temperatures under various conditions.

Appendix B Acoustic Output Reporting Table (60601-2-37)

Acoustic Output Data for 75 L53 EA Transducer

Detailed acoustic output parameters for the 75L53EA transducer in M-mode.

Eickemeyer MAGIC 6000 Specifications

General IconGeneral
BrandEickemeyer
ModelMAGIC 6000
CategoryMedical Equipment
LanguageEnglish

Related product manuals