EU Directives Help-5
IQ 2000/5000 Installation Manual
Products covered by this declaration are IQ-2000 servo amplifiers as follows:
PDM-010 P/N 9101-2141 (16MHz Clock)
PDM-020 P/N 9101-2142 (16MHz Clock)
PDM-030 P/N 9101-2143 (16MHz Clock)
PDM-010 P/N 9101-2161 (20MHz Clock)
PDM-020 P/N 9101-2162 (20MHz Clock)
PDM-030 P/N 9101-2163 (20MHz Clock)
PDM-075 P/N 9101-2164 (20MHz Clock)
These amplifiers must be used as part of a system incorporating motors and shielded motor cables
supplied by Reliance Motion Control, and installed in accordance with the installation instructions
contained in the document “IQ-2000 Installation Requirements for Compliance to European Direc-
tives”, available by request from the manufacturer, and the specific instructions in the product man-
ual.
Installation must be in a grounded metallic enclosure and all shields must be bonded to the enclosure
wall where they pass through it. An AC line filter of an approved type must be used for the supply to
the amplifier. When so installed the EMC requirements of the following European standards are met:
Emissions: EN 55011: 1993
(CISPR 11) Group 1 class A
Immunity EN 50082-2: 1995
Electrostatic Discharge EN 61000-4-2
Radiated RF IEC 801-3
Electrical Fast Transient EN 61000-4-4
Conducted RF ENV 50141
Magnetic Fields EN 61000-4-8
Electro-Craft, Ltd, Fourth Avenue, Crewe, Cheshire, CW1 1XL, UK