97
ADVANCED USER GUIDE
Commander SX
IP66/Nema 4X variable speed drive
MENU 11: SERIAL LINK - DRIVE CHARACTERISTICS - MISCELLANEOUS
CONTROL TECHNIQUES
3854 en - 03.2008 / b
13 - MENU 11: SERIAL LINK - DRIVE CHARACTERISTICS - MISCELLANEOUS
13.1 - List of parameters in Menu 11
Parameter Name Type Adjustment range Factory setting
User
setting
11.01 Parameter 46 set-up R-W 0.00 to 21.51 6.04
11.02 Parameter 47 set-up R-W 0.00 to 21.51 8.10
11.03 Parameter 48 set-up R-W 0.00 to 21.51 7.15
11.04 Parameter 49 set-up R-W 0.00 to 21.51 7.33
11.05 Parameter 50 set-up R-W 0.00 to 21.51 8.41
11.06 Parameter 51 set-up R-W 0.00 to 21.51 1.05
11.07 Parameter 52 set-up R-W 0.00 to 21.51 1.10
11.08 Parameter 53 set-up R-W 0.00 to 21.51 1.29
11.09 Parameter 54 set-up R-W 0.00 to 21.51 1.30
11.10 Parameter 55 set-up R-W 0.00 to 21.51 2.04
11.11 Parameter 56 set-up R-W 0.00 to 21.51 2.06
11.12 Parameter 57 set-up R-W 0.00 to 21.51 2.07
11.13 Parameter 58 set-up R-W 0.00 to 21.51 6.01
11.14 Parameter 59 set-up R-W 0.00 to 21.51 6.09
11.15 Parameter 60
set-up R-W 0.00 to 21.51 5.18
11.16 Parameter 61 set-up R-W 0.00 to 21.51 5.06
11.17 Parameter 62 set-up R-W 0.00 to 21.51 5.11
11.18 Parameter 63 set-up R-W 0.00 to 21.51 5.12
11.19 Parameter 64 set-up R-W 0.00 to 21.51 11.42
11.20 Parameter 65 set-up R-W 0.00 to 21.51 11.43
11.21 Parameter scaling R-W 0 to 9.999 1.000
11.22 Unit displayed at power-up R-W 0 to 5 0
11.23 Serial address R-W 0 to 247 1
11.24 Serial mode RO/P 0 or 1 - -
11.25 Baud rate R-W 0 to 9 6
11.26 Min comms transmit delay R-W 0 to 250 ms 2
11.27 Modbus RTU frame format R-W 0 to 3 0
11.28 Not used
11.29 Drive software version RO/P 1.00 to 9.99 - -
11.30 User security code R-W 0 to 9999 0
11.31 User drive mode R-W 0 to 3 1
11.32 Max. drive current rating RO/P 1.5 to 75.0 A - -
11.33 Drive voltage rating RO/P 200 to 480 V - -
11.34
Not used
to
11.40
11.41 Status mode time-out R-W 10 to 250 s 240 s
11.42 Parameter cloning R-W 0 to 3 0
11.43 Factory settings R-W/ 0 to 2 0
11.44 Quick setup menu access R-W 0 to 2 0
11.45 Motor parameter select R-W 0 or 1 0
11.46 Preset configuration select R-W/P 0 to 13
PT version = 11
Other = 0
11.47 Display duration in alternating mode R-W 0 to 250 s 5 s
11.48 Last preset configuration RO 0 to 12 - -
11.49 Parameter displayed at power-up R-W 0.00 to 21.51 0.00
11.50
Not used
to
11.58
11.59 Drive variant R-W 0 to 99 -
11.60 Drive identification code RO/P 0 to 32000 - -
11.61 Advanced menu access code R-W 0 to 9999 149