Menus 15 to 17
SM-EZMotion
Parameter
structure
Keypad and
display
Parameter
x.00
Parameter
description format
Advanced parameter
descriptions
Macros
Serial comms
protocol
Electronic
nameplate
Performance RFC mode
338 Unidrive SP Advanced User Guide
www.controltechniques.com Issue Number: 10
157 Y File Corruption Error - Consult Factory
158 Y File Corruption Error - Consult Factory
159 Y File Corruption Error - Consult Factory
160 Y File Corruption Error - Consult Factory
161 Y File Corruption Error - Consult Factory
162 Y File Corruption Error - Consult Factory
163 Y File Corruption Error - Consult Factory
164 Y File Corruption Error - Consult Factory
165 Y File Corruption Error - Consult Factory
166 Y
Program Error - EZMotion Parameter
Write Out of Range
Value written to SM-EZMotion
parameter in user program is out of
range
171 Y Invalid Slot 1 Selection
Solutions Module selected for Slot 1 in
PowerTools Pro file does not match
actual module type installed
Switch module located in Slot 1 to match
module type selected in PowerTools Pro file.
Alternatively, update the PowerTools Pro
configuration to match the module type
actually installed, and then re-download the
configuration.
172 Y Invalid Slot 2 Selection
Solutions Module selected for Slot 2 in
PowerTools Pro file does not match
actual module type installed
Switch module located in Slot 2 to match
module type selected in PowerTools Pro file.
Alternatively, update the PowerTools Pro
configuration to match the module type
actually installed, and then re-download the
configuration.
173 Y Invalid Slot 3 Selection
Solutions Module selected for Slot 3 in
PowerTools Pro file does not match
actual module type installed
Switch module located in Slot 3 to match
module type selected in PowerTools Pro file.
Alternatively, update the PowerTools Pro
configuration to match the module type
actually installed, and then re-download the
configuration.
174 Y File Corruption Error - Consult Factory
175 Y Module Output Overload
SM-EZMotion module can only supply
20mA maximum total output current. If
this fault occurs, the digital output
device attached to the module outputs
is drawing too much current.
Modify circuitry of devices connected to the
SM-EZMotion module digital outputs so that
they draw no more than 20mA total.
Error
Code
(Pr x.50)
Cause
Trip?
Error Possible Reason Possible Solution