Technical data Proline Promag W 400 EtherNet/IP
132 Endress+Hauser
Light emitting diodes (LED)
Status information Status indicated by various light emitting diodes
The following information is displayed depending on the device version:
Supply voltage active
Data transmission active
Device alarm/error has occurred
EtherNet/IP network available
EtherNet/IP connection established
Low flow cut off The switch points for low flow cut off are user-selectable.
Galvanic isolation The following connections are galvanically isolated from each other:
Outputs
Power supply
Protocol-specific data EtherNet/IP
Protocol The CIP Networks Library Volume 1: Common Industrial Protocol
The CIP Networks Library Volume 2: EtherNet/IP Adaptation of CIP
Communication type 10Base-T
100Base-TX
Device profile Generic device (product type: 0x2B)
Manufacturer ID 0x49E
Device type ID 0x1067
Baud rates Automatic ¹⁰⁄₁₀₀ Mbit with half-duplex and full-duplex detection
Polarity Auto-polarity for automatic correction of crossed TxD and RxD pairs
Supported CIP connections Max. 3 connections
Explicit connections Max. 6 connections
I/O connections Max. 6 connections (scanner)
Configuration options for
measuring device
DIP switches on the electronics module for IP addressing
Manufacturer-specific software (FieldCare)
Add-on Profile Level 3 for Rockwell Automation control systems
Web browser
Electronic Data Sheet (EDS) integrated in the measuring device
Configuration of the EtherNet
interface
Speed: 10 MBit, 100 MBit, auto (factory setting)
Duplex: half-duplex, full-duplex, auto (factory setting)
Configuration of the device
address
DIP switches on the electronics module for IP addressing (last octet)
DHCP
Manufacturer-specific software (FieldCare)
Add-on Profile Level 3 for Rockwell Automation control systems
Web browser
EtherNet/IP tools, e.g. RSLinx (Rockwell Automation)
Device Level Ring (DLR) No
Fix Input
RPI 5 ms to 10 s (factory setting: 20 ms)
Exclusive Owner Multicast Instance Size [byte]
Instance configuration: 0x68 398
O → T configuration: 0x66 56
T → O configuration: 0x64 32
Exclusive Owner Multicast Instance Size [byte]