C8-B/C12-B Service Manual Maintenance Disclosure Scope: Maintenance Trained Personnel Only
(C) Seiko Epson Corporation 2-179 Rev.1
Disconnect the Air Tube.
1. Remove the tube from the fitting.
2. Use an 8-mm wrench to rotate the nut, and remove the metal fitting.
5
Fitting
Nut
Air Tube
Removing the Motor Unit
2
7
6
5
2
3
4