EasyManua.ls Logo

Epson LQ-510 - Page 65

Epson LQ-510
226 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
REV.-A
PRINCIPLES OF OPERATION
EA1 is used to detect excessive output current. Figure 2-29 illustrates the mechanism. The output voltage
is input to the negative terminal, and in order for equal voltage to appear at the positive terminal:
(OUTPUT VOLTAGE)
X
R35
R34/(R39 // R34) = I
R35 becomes the load current flow (see Figure 2-29). In other words, higher current than this will trigger
over-current protection, the output voltage will be reduced, and the current will, thereby, be restricted.
R35
10K
Figure 2-29. Over-Current Protection (OCP)
LQ-510
2-23

Table of Contents

Other manuals for Epson LQ-510

Related product manuals