ADJUSTMENT TF Adjustments 259
Confidential
[Blue]: Button or menu name on the program screen / [Black]: Button or menu name on the operation panel of the printer
Figure 4-61. Set position of the thickness gauge on the full side
15. Confirm both Green LED and Orange LED of the sensor light.
16. Attach the adjustment screw.
17. Check the color of the LEDs, rotate the adjustment screw on the full side
clockwise to move the sensor position upward.
Adjust the sensor position up to when the LEDs change from “Green & Orange” to
“Green”.
18. Remove the 1.55 thickness gauge, then place the 1.88 thickness gauge.
19. Confirm both Green LED and Orange LED of the sensor light up.
20. Tighten the two screws loosened in Step 2 on the home side.
21. Click [OK]. The TABLE ASSY is moved from the printer to the front side.
22. Place the 1.30 gauge in the middle of the PLATEN.
Figure 4-62. Set position of the thickness gauge on the full side
23. Press the [Operate movable base] button in the panel to retract the TABLE
ASSY inside the printer.
24. The adjustment is complete normally if no error occurs.
25. Press the [Operate movable base] button in the panel to move the TABLE ASSY
to the front of the printer.
26. Remove the 1.30 thickness gauge, then place the 1.88 gauge.
27. Press the [Operate movable base] button in the panel to retract the TABLE
ASSY inside the printer.
28. The adjustment is complete normally if an error occurs.
29. Press the [Operate movable base] button in the panel to move the TABLE ASSY
to the front of the printer.
30. Remove the adjustment screws attached in Step 9 and Step 16.
Check the lighting status of the LEDs on only home side. The LED
of the sensor on the full side always lights orange.