SC-F2000 Revision C
TROUBLE SHOOTING Remedies for Service Call Error 37
Confidential
141A
Pump Motor
overload error
Overcurrent to the Pump Motor was detected.
Pump Motor encoder cable disconnection
Pump Motor cable disconnection
Irregular load
Pump Motor encoder failure
Pump Motor failure
1. Is there any problem such as disconnection or a
damaged cable in the connection below?
Pump Motor (Pump Motor encoder) to MAIN
BOARD
2. Does the Pump Motor encoder work properly?
Check it using the Service Program.
Replace the Pump Motor encoder and Pump Motor
(PUMP CAP ASSY). (Page 143)
141B
Pump Motor
over speed error
The Pump Motor was driven at a speed faster than a
predetermined one during deceleration.
Irregular load
Pump Motor encoder failure
Pump Motor driver failure
Does the Pump Motor encoder work properly? Check
it using the Service Program.
1. Replace the Pump Motor encoder (PUMP CAP
ASSY). (Page 143)
2. Replace the MAIN BOARD. (Page 95)
141C
Pump Motor
reversing error
The number of occurrences of reversing the Pump
Motor has reached a predetermined limit.
The polarity of Pump Motor encoder cable is
opposite.
The polarity of Pump Motor cable is opposite.
1. Is there any problem such as disconnection or a
damaged cable in the connection below?
Pump Motor (Pump Motor encoder) to MAIN
BOARD
2. Does the Pump Motor encoder work properly?
Check it using the Service Program.
Replace the Pump Motor encoder (PUMP CAP
ASSY). (Page 143)
141D
Pump Motor
driving time-out error
Abnormally-long driving duration of the Pump Motor
was detected.
Irregular load
Firmware becomes out of control.
---
Replace the MAIN BOARD. (Page 95)
141E
Pump Motor
velocity deviation error
The Pump Motor was driven at a speed abnormally
faster than a predetermined one during acceleration or
deceleration.
Irregular load
Pump Motor encoder failure
Pump Motor failure
Pump Motor driver failure
Does the Pump Motor encoder work properly? Check
it using the Service Program.
1. Replace the Pump Motor encoder and Pump
Motor (PUMP CAP ASSY). (Page 143)
2. Replace the MAIN BOARD. (Page 95)
141F
Pump Motor
lock error
The Pump Motor was driven at a speed abnormally
slower than a predetermined one during operation.
Irregular load
Pump Motor encoder failure
Pump Motor failure
1. Is there any problem such as disconnection or a
damaged cable in the connection below?
Pump Motor (Pump Motor encoder) to MAIN
BOARD
2. Does the Pump Motor encoder work properly?
Check it using the Service Program.
Replace the Pump Motor encoder and Pump Motor
(PUMP CAP ASSY). (Page 143)
1431
PUMP CAP ASSY
life error
The PUMP CAP ASSY has reached the end of its
service life. (The total number of revolutions of the
Pump Motor has reached a predetermined limit)
---
Replace the PUMP CAP ASSY (Page 143) and
reset the counter (Page 221).