The HmRef signal is inactive initially, and the Motor starts homing in negative direction at high speed.
If the Motor reaches the limit switch, it automatically changes to run in positive direction at high
speed.
After reaching the rising edge of the HmRef signal, the Motor decelerates and continues to run in
positive direction at low speed.
After reaching the falling edge of the HmRef signal, the Motor changes to run in negative direction at
low speed, and stops at the rising edge of the HmRef signal.
Deceleration point signal active at homing start:
The HmRef signal is active initially, and the Motor directly starts homing in positive direction at low
speed.
After reaching the falling edge of the HmRef signal, the Motor changes to run in negative direction at
low speed.
After reaching the rising edge of the HmRef signal, the Motor stops.