Summa Series Servodrive Product Manual
Trial Operation
Document Version: V1.01
(Dec, 2019)
© 2019 ESTUN Automation Co., Ltd. All right reserved.
8-12
Step 4 Set the relevant parameters for the operation patterns PJOG0 and PJOG1.
Rotation Number: Set the numbers of rotation the Motor will run in the operation pattern PJOG0 or
PJOG1.
NOTE: The Motor can be run in reverse when this parameter is set to a negative value.
Rotation Speed: Set the Motor running speed in the operation pattern PJOG0 or PJOG1.
Acceleration/Deceleration Time: Set the time it takes for the Motor runs to Rotation Speed or the
Motor stops from Rotation Speed.
Stop Time: Set the hold time when the Motor stops running in the operation pattern PJOG0 or
PJOG1, and then switches to the other operation pattern.
Step 5 Click Apply to complete the settings.
Step 6 Click Servo Off / Servo On for supplying power to the Motor.
Step 7 Click Run.
The Motor will be run between the operation patterns PJOG0 and PJOG1.
Click Stop for stopping the Motor running.
The Motor can be stopped when you close ESView V4 or PJOG window.