Summa Series Servodrive Product Manual
Appendix
Document Version: V1.01
(Dec, 2019)
© 2019 ESTUN Automation Co., Ltd. All right reserved.
12-7
No.
Index
Name
Range
Unit
Default
When Enabled
Pn006
316A
Application Function
Selections 6
0000 to 0001
0001
After restart
Pn006.0: Bus Selection
0
Do not use the Bus. Select the control method by the setting of
Pn005.1.
1
Use EtherCAT.
Pn006.1: Reserved setting (Do not change).
Pn006.2: Reserved setting (Do not change).
Pn006.3: Reserved setting (Do not change).
Pn007
316B
Application Function
Selections 7
0000 to 1120
0010
After restart
Pn007.0: Reserved setting (Do not change).
Pn007.1: Power Supply Selection
0
Single-phase AC, for the Drives of ED3S-15A* to ED3S-30A*, this
setting is unavailable.
1
Three-phase AC
2
DC
Pn007.2: Torque Limit Action When Undervoltage Occurs
0
Disabled.
1
Enabled.
Pn007.3: AC Supply Frequency
0
50 Hz
1
60 Hz