2nd Channel
Current Detection
Error
The average of the Iv digital quantity
read from the 2st channel for 2048
times is greater than 1500 during Servo
ON.
Contact ESTUN or the
Authorized Distributor.
The handshake between DSP and
FPGA failed.
Contact ESTUN or the
Authorized Distributor.
IPM Junction
Temperature
Error
The junction temperature of the
Intelligent Power Module is greater
than the setting value of Pn534.
An overcurrent flowed through the
Intelligent Power Module.
Check if the Motor was
blocked.
The bus voltage is greater than 420 V.
Try to modify the
Motor running track to
make it run more
smoothly.
The bus voltage is lower than 165 V.
If the main power
supply system is
normal, contact
ESTUN or the
Authorized Distributor.
Discharge
Resistor
Damaged
The discharge resistor is damaged or
unconnected.
Check whether the
regenerative resistor is
connected
The discharging operation is abnormal.
Check the sizing of
regenerative resistor.
The temperature of the Intelligent
Power Module is greater than
threshold.
Check the ambient
temperature and
derating the load.
Charging
Resistor
Overload
The main circuit power supply was
frequently turned ON and OFF.
Delay the interval
between the two power-
up.
The circuit of the Dynamic Brake is
damaged.
Contact ESTUN or the
Authorized Distributor.
The fan on the control board had not
worked for more than 30 seconds.
Contact ESTUN or the
Authorized Distributor.
Temperature
Sensor of Drive
Board Error
The NTC temperature sensor is not
connected or broken
Contact ESTUN or the
Authorized Distributor.
Main Circuit
Charging Error
The charging resistor on the main
circuit was damaged or the P1 terminal
and the P2 terminal are not shorted.
Check if the P1
terminal and P2
terminal is properly
connected.
Main Circuit
Grounding Error
The main circuit was not grounded.
Check if short cut of
Drive or Motor occurs.
The voltage was low for more than one
second for phase R, S, or T when the
main power supply was ON.
Check if the three-
phase power supply is
connected to the Drive
properly.