Summa Series Servodrive Product Manual
Document Version: V1.01
(Dec, 2019)
© 2019 ESTUN Automation Co., Ltd. All right reserved.
The stop process is completed, and all the drive functions are inhibited.
Parameter setting is allowed for users to eliminate faults.
The control commands and state switchover are described as follows:
Natural transition, and no control
command is required.
Initialization → No Fault
Natural transition, and no control
command is required.
If an error occurs during
initialization, the Drive directly
goes to state 13.
Ready → Wait to switch on
Wait to switch on → Running
Running → Wait to switch on
Wait to switch on → Ready
Wait to switch on → No Fault
Set 605Ah to a value among 0 to 2.
Natural transition is performed after
stop, and no control command is
required.
Once a fault occurs in any state
other than Fault, the Drive
automatically switchovers to the
stop at fault state, without control
command.
Natural transition after stop at fault,
and no control command is
required.
Set 605Ah to a value between 5 and
6. After the stop process is
completed, 0x0F is sent after the
stop process is completed.