EasyManuals Logo

Etel DSC Series User Manual

Etel DSC Series
370 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #209 background imageLoading...
Page #209 background image
ETEL Doc. - Operation & Software Manual # DSC2P 903 / Ver. F / 3/6/05 Chapter C: System functions
Operation & Software Manual
Direct Drives & Systems 209
Remark: The TEB synchronization must be activated! If it is not the case, the real-time values read by
the DSMAX could be not updated at each cycle! Then, parameter K87 must be equal to 1 for a
DSC2P/DSC2V and to 257 for a DSCDP, DSCDL and DSCDM.
When K219 = 0, the controller does not send any value to the RTM channels.
Example:
The measured position (monitoring M7) and the theoretical force (monitoring M30) of the axis 5 are sent to the
master.
K219:0.5=0x03000007 ;Register 1 is monitoring M7 (03 = monitoring M; 07 = monitoring number)
K219:1.5=0x0300001E ;Register 2 is monitoring M30 (03 = monitoring M; 1Eh= 30 = monitoring number)
K Name Byte # Comment
K219 RTM register
0
1
Number of the register to be sent
2 Depth of the register (only available for the parameters K)
3
1 = the register sent is a user's variable X
2 = the register sent is a parameter K
3 = the register sent is a monitoring M

Table of Contents

Other manuals for Etel DSC Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Etel DSC Series and is the answer not in the manual?

Etel DSC Series Specifications

General IconGeneral
BrandEtel
ModelDSC Series
CategoryController
LanguageEnglish

Related product manuals