15.18 Special labels (79, 80) example
:79.2 ;Autostart label (the sequence starts automatically)
MMD.2=17 ;Sets the rotary S-curve movement
PWR.2=1 ;Power on
WTM.2 ;Waits until the movement is finished
IND.2 ;Starts the homing
WTM.2 ;Waits until the movement is finished
POS.2=0.00000 ;Goes to the position 0 (ISO unit)
WTM.2 ;Waits until the movement is finished
X1.2=0 ;Sets user’s variable X1 of axis 2 to 0
X100.2=0 ;Sets user’s variable X100 of axis 2 to 0
:30.2 ;Label 30
XAC.2=X1.2 ;Copies the value of the user’s variable X1 of the axis 2 in the accumulator (XAC)
IEQ.2=10,50 ;Goes to label 50 if XAC = 10
POS.2=10.0000 ;Goes to the position 10 (ISO unit)
WTM.2 ;Waits until the movement is finished
POS.2=0 ;Goes to the position 0 (ISO unit)
WTM.2 ;Waits until the movement is finished
X1.2+=1 ;Adds 1 to the previous value of the user’s variable X1 of the axis 2
JMP.2=30 ;Jumps to label 30
:50.2 ;Label 50
PWR.2=0 ;Power off
WTT.2=2.00000 ;Waits for 2 (ISO unit)
X20.2+=1 ;Adds 1 to the previous value of the user’s variable X20 of the axis 2
JMP.2=79 ;Jumps to label 79
:80.2 ;Label 80 (the sequence jumps automatically to this label if an error occurs)
PWR.2=0 ;Power off
X100.2=25 ;Sets user’s variable X100 of axis 2 to 25
END.2 ;Stops the execution of the sequence

Table of Contents

Other manuals for Etel DSC Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Etel DSC Series and is the answer not in the manual?

Etel DSC Series Specifications

General IconGeneral
BrandEtel
ModelDSC Series
CategoryController
LanguageEnglish

Related product manuals