350
Direct Drives & Systems
Chapter E: Appendixes ETEL Doc. - Operation & Software Manual # DSC2P 903 / Ver. F / 3/6/05
19.3 Errors for DSCDL
DSCDP errors
144
QUARTZ
OSCILLAT
Difference between the oscillator
and quartz is too big
xxOFF
150
INITIALI
MOTOR 1
Bad measure during initialization
process when K90=1
x
K90, K91,
K98
Motor cable x OFF
151
INITIALI
MOTOR 2
Bad time measurement during
initialization process when K90=1
x
K90, K91,
K98
Motor cable x OFF
152
INITIALI
POWER OF
Error when the controller is disabled
during initialization process when
K90=1 or 2
xOFF
153
INITIALI LOW
CUR
Too low force when K90 = 6.
Increase K91
K91,
K101
xOFF
154
INITIALI
HIGH CUR
Too high force when K90 = 6.
Decrease K91
K91,
K101
xOFF
155
INITIALI LOW
TIME
Too low time when K90 = 6. Increase
K101
K91,
K101
xOFF
156
TIMEOUT
AUT CMD
Time-out during AUT command x x
K90 to
K98 K79
Motor or
encoder cable
xOFF
157
INIT BAD
PHASING
Error during the initialization
process when K90=2
xx
K90 to
K98 K79
Motor or
encoder cable
xOFF
190
SWITCH OFF
& ON
The controller has executed a save
operation (SAV command)
xOFF
M64
Displayed
message
Description Enc Mot Hrd Bad K PS TEB EBL2 Other
SW
res
Hw
res
Brk
DSCDL errors
2
OVER
CURRENT1
The current measured in phase 1 is
greater than K83
xx
K60, K80,
K81, K83,
K98
xOFF
3
OVER
CURRENT2
The current measured in phase 2 is
greater than K83
xx
K60, K80,
K81, K83,
K98
xOFF
4 I2T ERROR
This occurs when M67 becomes
greater than K85. This is a power
protection (of the motor and/or the
controller)
K1, K2,
K4, K52,
K53, K56,
K84, K85
Friction / duty
cycle
xOFF
5
OVER
TEMPERAT
The temperature of the controller is
greater than 70°C. This is measured
by a thermostat mounted on the heat
sink
Heat evacuation x OFF
6
OVER
VOLTAGE
The power voltage (Vpower) in volt
in greater than K149/100
K149 x OFF
8
+5V
SHUTDOWN
Error that occurs when the +5V of
the controller becomes lower than
4.5V
xx xOFF
9
UNDER
VOLTAGE
The power voltage (Vpower) in volt is
lower than K147/100
K147 x OFF
10
OFFSET
CURERROR
Error in offset of current
measurement. The offset measured
is greater than 8% of the maximum
current of the controller (M82)
xxOFF
13
SENSOR
TEMP ERR
The temperature sensor does not
respond
xxOFF
16
ENDAT
OVERFLOW
The calculated EnDat position is too
big. Decrease K77
xK77 xON
M64
Displayed
message
Description Enc Mot Hrd Bad K PS TEB EBL2 Other
SW
res
Hw
res
Brk

Table of Contents

Other manuals for Etel DSC Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Etel DSC Series and is the answer not in the manual?

Etel DSC Series Specifications

General IconGeneral
BrandEtel
ModelDSC Series
CategoryController
LanguageEnglish

Related product manuals