EasyManuals Logo

EVOCA Cafection Symbol User Manual

EVOCA Cafection Symbol
87 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #67 background imageLoading...
Page #67 background image
67
www.cafection.com 800-561-6162
DS2212NSA Rev. 1 2023-04
SERVICE & INSTALLATION MANUAL - Symbol
7.8.6 Brew Group (continued)
Crush hazard. Handle the brew group cautiously.
Brew Group Assembly Sanitizing Treatment
Frequency: quarterly or every 5,000 cycles
Regular sanitation treatments of the brew group
assembly prevent residues from affecting the
vacuum in the mechanism and altering the taste of
the beverages.
Please refer to the section7.2 of this manual for
sanitizing instructions.
7.8.7 Fans
Frequency: quarterly or as needed
Visually inspect the two (2) fans located on the right
side of the machine.
1. Turn OFF the unit and unplug the power supply
to stop the fans.
Front Fan
2. Open the brewer's door.
3. Remove the two (2) fixation bolts, then
remove the fan to access its blades
4. Unplug the fan.
Back Fan
5. Remove the back panel.
6. Unplug the fan, then remove the two (2)
fixation bolts.
7. Remove the fan and its guard to access its
blades.
8. Wipe the two (2) fans clean with a dry
disposable towel.
9. Reinstall parts, plug the fans and the machine
in, then turn the brewer back ON.
Back Fan
Front Fan
Cleaning and Sanitizing

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EVOCA Cafection Symbol and is the answer not in the manual?

EVOCA Cafection Symbol Specifications

General IconGeneral
BrandEVOCA
ModelCafection Symbol
CategoryCoffee Maker
LanguageEnglish