Tuning and Debugging EPICenter
EPICenter Concepts and Solutions Guide
138
</table>
<table>
<oid name="variableName2" dataLabel="Label/description" />
<oid name="variableName3" dataLabel="Label/description" />
</table>
<scalar>
<oid name="scalarVariable1" dataLabel="Label/description" />
<oid name="scalarVariable2" dataLabel="Label/description" />
</scalar>
<scope ipAddress="123.234.345.456" />
<scope ipAddress="123.234.345.789" />
</collection>
</collections>
Within the outermost collections statement, you can define multiple individual collections, each
bracketed with
<collection name= ... > </collection>
The collection properties must be defined in the collection statement at the beginning of each collection
definition:
Table OIDs are defined in
<oid ... > statements, included between <table> and </table>
statements. OIDs from different tables must be put in separate
<table> statements. The label portion of
the statement appears in the MIB Collections Detail report, and as a heading in the exported data file.
Scalar OIDs are defined in
<oid ... > statements included between a <scalar> and </scalar>
statement.
The devices that should be polled are specified by IP address in <
scope ipAddress ...> statements,
one for each IP address.
The completed file must be named
collections.xml, and placed in the user/collections directory. The
Reload button in the MIB Poller Summary report will load the collections.xml specification, and begin
the collection process if the
initialState property specifies “running.”
Figure 62 on page 142 shows an example of an actual
collections.xml file.
Table 6: Control properties for a MIB collection specification
name A name for the collection
pollingIntervalInSecs The interval at which EPICenter should poll for the variables defined in this collection
initialState Whether this collection should start running immediately upon loading (values are
“running” and “stopped”)
saveData Whether the collected data should be saved to the EPICenter database (“yes” or “no”)
maxPollsPerDevice The maximum number of poll result sets that should be saved in the database
deletePercentage The percentage of the saved data that should be deleted when the file reaches it
specified limit

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Extreme Networks EPICenter Guide and is the answer not in the manual?

Extreme Networks EPICenter Guide Specifications

General IconGeneral
BrandExtreme Networks
ModelEPICenter Guide
CategorySoftware
LanguageEnglish

Related product manuals