The AlarmMgr Utility
EPICenter Concepts and Solutions Guide
247
Table 14 specifies the options you can use with this command:
You can specify only one EPICenter server (database) in a command. If you want to display alarms
from multiple EPICenter databases, you must use a separate command for each server.
The options for specifying the relevant time period (-h, -d, and -y) are mutually exclusive and
cannot be combined.
You can specify filter options such as an alarm name or device (IP address) only once per command.
If you want to display information for a several values of a filter option, such as several alarm
names, devices, severity levels, etc., you must execute an AlarmMgr command for each value of the
filter option. For example, to display alarms for two different devices, you must execute two
AlarmMgr commands.
Table 14: AlarmMgr command options
Option Value Default
-user <username> EPICenter user name. This option is required. None
-password <password> EPICenter user password. If the password is blank, do not include
this argument.
No
password
-host <hostname | IP
address>
EPICenter server hostname or IP address localhost
-port <port> EPICenter server port number 80
-h <N> Display alarms that occurred within the last N
hours
These options are
mutually exclusive
and may not be
combined
Last 300
alarms
-d <N> Display alarms that occurred N days ago
-y Display alarms that occurred yesterday
-c <category> Display alarms that occur for a specific
category. Category specification is case
insensitive. Must be quoted if category name
includes spaces or other delimiters.
When these
options are
combined, an
alarm must meet
all criteria to be
included in the
results.
Each of these
options may be
specified only
once.
All
categorie
s
-s <severity> Display alarms that occur for a specific
severity. Severity specification is case
insensitive.
All
severity
levels
-dip <IP address> Display alarms that occur for a specific device
as specified by IP address.
All
devices
-p <port> Display alarms that occur for a specific port on
the device specified with the -dip option.
All ports
-an <alarm name> Display alarms that occur for a specific alarm.
Alarm name specification is case insensitive.
Must be quoted if alarm name includes spaces
or other delimiters.
All
alarms
-a Display all acknowledged alarms. All
alarms
-u Display all unacknowledged alarms.
-f <file specification> Name of file to receive output. If you do not specify a path, the file
is placed in the current directory. If the file already exists, it is
overwritten.
Comman
d window
(stdout).
-help Displays syntax for this command None

Table of Contents