DTP CrossPoint 84 Series Matrix Switchers • DSP SIS Commands 144
Command Function
SIS Command
(Host to Unit)
Response
(Unit to Host)
Additional description
Read a digital DSP trim
or mix-point
EHX6)AU} X6!] Object ID X6) is set to a value of X6!.
Example:
EH30103AU} 75]
Line input 2 right trim is set to +7.5 dB.
Audio Mute
Audio mute
EMX6)*1AU} DsMX6)*1] Mute object ID X6).
Example:
EM60006*1AU} DsM 60006*1]
Mute output 4, left, analog volume.
Audio unmute
EMX6)*0AU} DsMX6)*0] Unmute object ID X6).
Example:
EM40000*0AU} DsM 40000*0]
Unmute mic input 1 gain (pass audio).
Read audio mute
EMX6)AU} X6@] X6@: 0 = mute off, 1 = mute on.
Phantom Power
NOTE: The phantom power commands are valid only for the mic input gain object IDs (Y6)s 40000 through 40003).
Phantom power on
EZX6)*1AU} DsZX6)*1] Turn phantom power on for object ID X6).
Example:
EZ40000*1AU} DsZ 40000*1]
Turn phantom power on for mic 1.
Phantom power off
EZX6)*0AU} DsZX6)*0] Turn phantom power off for object ID X6).
Read phantom power
status
EZX6)AU} X6)*X6@] X6@: 0 = phantom power off.
1 = phantom power on.
Group Masters
NOTES:
• See Group masters on page100, for more information about audio group masters.
• A group must have assigned members for these commands to have an effect.
•
For
X6$
, a positive (+) value is assumed unless a negative (-) value is specified.
•
If entering a
X6$
value outside the valid range for the group or outside the soft limits, the DTP CrossPoint responds with an
invalid parameter (
E13) error.
Set a group fader
control
EDX6#*X6$GRPM} GrpmDX6#*X6$] Set the group fader to a value of X6$.
Example:
ED2*-293GRPM} GrpmD2*-293]
Set the group 2 fader control to -29.3dB.
Raise a group fader
control
EDX6#*X6%+GRPM
}
GrpmDX6#*X6$] Increase the level of the X6# group fader
by
X6%dB.
Example:
ED2*30+GRPM} GrpmD2*-263]
Raise the group 2 fader 3dB (from
-29.3dB to -26.3dB, starting from the
level set in the Set a group fader control
example, above.
Lower a group fader
control
EDX6#*X6%-GRPM} GrpmDX6#*X6$] Decrease the level of the X6# group fader
by
X6%dB.
View the group fader
control level
EDX6#GRPM} GrpmDX6#*X6$]
In verbose modes 1 and 2, the response
is simplified to
X6$].
Mute a group mute
control
EDX6#*1GRPM} GrpmDX6#*1] Mute all blocks in group X6#.
Clear (unmute) a group
mute control
EDX6#*0GRPM} GrpmDX6#*0] Umute all blocks in group X6#.
KEY: X6) = Object ID (gain control or mix-point) See the table beginning on page138.
X6! = Level value -100.0 dB to +80.0 dB, in 0.1 dB increments. Example: 56 = 5.6 dB.
NOTE: The valid range of the
X6!
level for a specific control depends on the control addressed.
X6@ = Mute and phantom power status
X6# = Group master group number 01 – 32
X6$ = Group fader setting dB value, in 0.1 dB increments. The valid range depends on the type of gain block
X6% = Group fader increment dB value, in 0.1dB increments, to raise or lower a group fader