ST80/ST80L Flow Meter GENERAL
Fluid Components International LLC 5
NEMA 4X, IP66/67 polyester powder coated aluminum or
optional 316L stainless steel.
Two (2) cable ports 1/2"-14 NPT or M20 x 1.5
Size: 3.27" W x 3.54" H x 3.9" L (83 mm x 90 mm x 99 mm)
■ Readout/Display (Option 1):
• Large backlit 2" x 2" [50 mm x 50 mm] LCD for display of digital
flow rate, analog bar graph of flow rate, total flow, and
temperature; user selectable engineering units, and alarm/fault
status indication.
• User programmable 17 alphanumeric character field
associated with each calibration group.
• Set-Up & Service mode displays text and service codes.
• Display is electronically rotatable in 90° increments to optimize
viewing angle.
Note: For units without the display option, the service port (USB)
lets a PC configure/manage the instrument via the ST80/ST80L
configurator utility.
■ Readout/Display and Optical Touch Buttons (Option 2)
Includes the Readout/Display Option 1 items, plus adds four
keypad/buttons for the user interface.
• Four (4) optical touch buttons for user programming of
instrument set-up and service interrogation.
• User programming and setup via the front panel.
• Optical touch button activation through front window – no need
to open enclosure to access or activate.
• Set and adjust the meter or interrogate diagnostics in-situ,
even in HazEx installation.
Other Options
■ Vortab Flow Conditioners
Available for all line size applications; standard choice with Model
ST80L (in-line).
■ Sun Shield
Shades main transmitter, electronics, and display from direct
sunlight; 316L stainless steel.
FCI P/N 023241-01 Integral transmitter
FCI P/N 023237-01 Remote transmitter
■ Ball Valves/Cable Glands
■ Certification and Testing Documentation
CMTR, NACE, PMI, 0
2
cleaning, radiography, dye penetrant,
hydrostatic or air pressure test, certificate of origin, certificate of
conformance, wake frequency strength, and more.
■ Field Service and Support
Start-up assistance, site commissioning and installation
validation, maintenance agreements, bus communications
integration and validation, and more.