Table A-1. List of Errors (cont)
ID Message Description
-410 Interrupted. Remote interface error. A command was received which
sends data to the output buffer, but the output buffer
contained data from a previous command. The output
buffer is cleared when power has been off, or after reset
command has been executed.
-420 Unterminated. Remote interface error. The calibrator was addressed to
talk but a command has not been received which sends
data to the output buffer.
-430 Deadlocked. Remote interface error. A command was received which
generates too much data to fit in the output buffer and the
output buffer is full. Command execution continues but all
data as lost.
-363 Input buffer overrun Remote interface error.
-110 Command header Remote interface error. A command was received that is
not valid for the calibrator. You may have misspelled the
command or it may not be a valid command.
-103 Invalid separator Remote interface error. An invalid separator was found in
command string. You may have used a comma instead of
a colon, semicolon, or blank space – or you may have
used blank space instead of comma.
-120 Numeric data Remote interface error.
-140 Character data Remote interface error.
-220 Invalid parameter Remote interface error. An invalid character string was
received. Check to see if you have enclosed the character
string in single or double quotes and that the string
contains valid ASCII character.
651 Impedance to high. Residual impedance is too high (SCAN, COMP). Don’t
use SACN and COMP mode in Loop/Line impedance
function or connect the calibrator to the socket with lower
residual impedance.
661 Test voltage too high. External test voltage too high. Use lower test voltage on
DUT
662 Test voltage unstable. External test voltage is not stable.
711 Value too large. Set up value too large. Set value in specified limits.
712 Value too small. Set up value too low. Set value in specified limits.
713 Negative value. Negative value is not permitted. Don’t set negative value.
801 Option not installed. Selected function is not available. Option not installed.
Current timeout. Maximum thermal load in ground bond, loop/line
resistance has been reached. Calibrator disconnected
output terminals. Leave the calibrator in STANDBY mode
for 5 minutes.