5-1
Chapter 5
Certifying Coaxial Cabling
Certifying coaxial cabling requires the optional DTX-COAX
coaxial adapters.
Setting the Reference
The reference procedure sets a baseline for insertion loss
and resistance measurements.
Run the tester’s reference procedure at the following times:
When you want to use the tester with a different smart
remote. You can reference the tester to two different smart
remotes.
Every 30 days. Doing so ensures maximum accuracy of test
results.
You do not need to set the reference after changing link
interface adapters.
Note
Turn on the tester and let it sit for 1 minute before
setting the reference. Set the reference only after
the testers have reached an ambient temperature
between 10
°
C and 40
°
C (50
°
F and 104
°
F).
To set the reference, do the following:
1
Attach coaxial adapters to the main and remote
testers, screw in the F-connector to BNC adapters; then
make the connections shown in Figure 5-1.
2
Turn the rotary switch to SPECIAL FUNCTIONS and turn
on the smart remote.
3
Highlight Set Reference; then press H. If both a
fiber module and copper adapter are attached, select
Link Interface Adapter.
4
Press P.

Table of Contents

Other manuals for Fluke DTX-MFM2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke DTX-MFM2 and is the answer not in the manual?

Fluke DTX-MFM2 Specifications

General IconGeneral
BrandFluke
ModelDTX-MFM2
CategoryControl Unit
LanguageEnglish

Related product manuals