EasyManua.ls Logo

Fluke DTX-MFM2 - Autotest in Far End Source Mode

Fluke DTX-MFM2
320 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DTX Series CableAnalyzer
Technical Reference Handbook
7-34
Autotest in Far End Source Mode
Use Far End Source mode to measure power or power loss
at one wavelength on individual fibers.
Far End Source mode requires a stand-alone optical source,
such as a DTX smart remote with a fiber module.
You can also use other sources, such as a Fluke Networks
SimpliFiber
®
source or LS-1310/1550 laser source.
Figure 7-16 shows the equipment required for measuring
loss in Far End Source mode.
Note
The Autotest in Far End Source mode does not
show a PASS/FAIL result, limit, or margin if the
selected test limit calculates loss based on fiber
length. An example of such a limit is the
TIA-568B Fiber Backbone limit. The tester does not
measure length in Far End Source mode.