DTX Series CableAnalyzer
Technical Reference Handbook
10-18
Table 10-2. Diagnosing Low-Level Network Problems (cont.)
Wire pairs 12 and 36 are reversed
Mix of 568A and 568B wiring standards.
Crossover cables used where not needed. They are typically used only between two switches or hubs.
Tester is connected to a NIC (network interface card) with a straight-through cable. The reversed result is normal in this
situation, since a NIC transmits on pair 12 while a switch or hub transmits on 36.
Note
The utilization, collision, and error percentages given below are only guidelines.
Acceptable percentages can vary among networks.
Utilization averaging above 40 %
Too many stations on the network.
Utilization spikes above 40 %
Broadcast storms.

Table of Contents

Other manuals for Fluke DTX-MFM2