The Summary screen, shown in Figure 2-6, tells you if the
test results met the selected test limit. This screen also
shows a status for each measurement:
E: PASS
F: FAIL
i: The results are for informational purposes only. The
measurement is not required by the selected test
limit.
U: The measurement is within the tester’s accuracy
uncertainty range. See page 3-12 for details.
To see the results for an individual measurement, use
D to highlight the test; then press H.
If the test failed, press
J Fault Info. for a diagnosis of the
fault. Figure 2-6 shows a typical diagnostic screen. The Next
Fault softkey is available if the tester detected more than
one fault. See Chapter 6 for more information on
diagnosing faults.
See Chapter 3 for details on twisted pair test results.
amd119f.eps
Figure 2-6. Autotest Summary and Diagnostic Screens