Custom Test Settings
Creating a Custom Fiber Type
11-3
11
To create a custom twisted pair limit:
1
Turn the rotary switch to SETUP; then select Tw is t ed
Pair.
2
Select Test Limit, press J More; then select Custom.
3
Press J Create.
4
On the Custom screen, select Name; then use the text
editing screen to enter a name for your custom limit.
Press
N when you are done.
5
On the Custom screen, select Use Default Values From,
select a test limit group; then select a limit as a baseline
for your custom limit.
6
The Custom screen shows other settings on multiple
tabs for the twisted pair limit. Use AD and
H to select settings to change. Use BC to move
among the tabs.
See page 3-3 for details on twisted pair test
parameters.
7
From the Custom screen, press N when you are done
creating the limit. The tester saves the custom limit in
the Custom list, with asterisks (*) before and after the
name.
Creating a Custom Fiber Type
You can create up to nine custom fiber types. A custom
fiber type includes the following settings:
•
Custom fiber name
•
Baseline limit for default settings
•
Index of refraction (n)
To create a custom fiber type:
1
Turn the rotary switch to SETUP; then select Fiber.
2
Select Fiber Type; then select Custom.
3
Press J Create.
4
On the Custom screen, select Name; then use the text
editing screen to enter a name for your custom fiber
type. Press
N when you are done.
5
On the Custom screen, select Use Default Values From,
select a fiber group; then select a fiber type as a
baseline for your custom fiber type.
-continued-