EasyManua.ls Logo

Fluke DTX-MFM2 - DTX Series Cableanalyzer Technical Reference Handbook

Fluke DTX-MFM2
320 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DTX Series CableAnalyzer
Technical Reference Handbook
3-4
Table 3-1. Twisted Pair Test Settings (cont.)
Setting Description
SETUP > Twisted
Pair > Outlet
Configuration
The Outlet Configuration setting determines which cable pairs are tested and which pair numbers are
assigned to the pairs. To see the wire map for a configuration, press
J Sample from the Outlet
Configuration screen. Selecting Custom lets you create a configuration. See page 11-1 for details.
T568A T568B USOC (1 or 2 Pair)
Token Ring
ATM/TP-PMD Straight
ATM/TP-PMD
Crossed
Ethernet
Ethernet Crossed
1 white/green
2 green
3 white/orange
4 blue
5 white/blue
6 orange
7 white/brown
8 brown
12
3
4
1 white/orange
2 orange
3 white/green
4 blue
5 white/blue
6 green
7 white/brown
8 brown
13
2
4
3 white/orange
4 blue
5 white/blue
6 orange
12
3 white/green
4 blue
5 white/blue
6 green
13
1 white/green
2 green
7 white/brown
8 brown
1
2
2
1
1
2
7
8
7
8
1
2
white/green
green
white/brown
brown
1 white/orange
2 orange
3 white/green
6 green
3
2
3
2
1
2
3
6
3
6
1
2
white/orange
orange
white/green
green

Table of Contents

Other manuals for Fluke DTX-MFM2