DTX Series CableAnalyzer
Technical Reference Handbook
13-16
WXWarning
Under no circumstances is this product intended
for direct connection to telephony inputs,
systems, or equipment, including ISDN inputs.
Doing so is a misapplication of this product, which
could result in damage to the tester and create a
potential shock hazard to the user.
Service Calibration Period
One year.
Standard Link Interface Adapters
² Cat 6/Class E permanent link adapters
• Plug type and life: shielded 8-pin modular (RJ45);
>5000 insertions
• Tests supported: shielded and unshielded cable, TIA Cat
3, 4, 5, 5e, and 6 and ISO/IEC Class C and D, and E
permanent link
• Cat 6/Class E channel adapters
• Plug type and life: shielded 8-pin modular (RJ45);
>5000 insertions
Tests supported: shielded and unshielded cable, TIA Cat 3, 4,
5, 5e, and 6 and ISO/IEC Class C and D channels
Cable Types Tested
• Shielded and unshielded twisted pair (STP, FTP, SSTP,
and UTP) LAN cabling:
• TIA Category 3, 4, 5, 5e, and 6: 100 Ω
• ISO/IEC Class C and D: 100 Ω and 120 Ω
Note
For availability of additional adapters that allow
testing to other performance standards, different
cabling types, or fiber optic cabling, contact Fluke
Networks.
Time for Autotest
Full 2-way Autotest of Category 6 UTP cable in 12 seconds
or less.