5.2 Function Code Tables
Control method and Data setting range
Torque limiter (Braking)
(Frequency rising limiter for
braking)
Service life of DC link bus
capacitor
0 to 87600 hours (updated in 10 hour units)
Maintenance interval (M1)
0 (Disable), 1 to 99990 hours (updated in 10 hour units)
Preset startup count for
maintenance (M1)
0 (Disable), 1 to 65535 times
Output current fluctuation
damping gain for motor 1
0000 to FFFF (in hexadecimal)
100 to 400 % (Motor rated magnetizing current for 100 %)
0.00: Disable
0.01 to 30.00 s
For adjustment by
manufacturer *9
For adjustment by
manufacturer *9
For adjustment by
manufacturer *9
Current input wire break
detection
0.0 (Alarm disable): 0.1 to 60.0 s
Continuous running at the
momentary power failure (P)
0.000 to 10.000 times
999: Manufacturer adjustment value
0.010 to 10.000 s
999: Manufacturer adjustment value
Cumulative run time of motor
1
0 to 99990 hours (updated in 10 hour units)
Change in cumulative motor run time (reset possible)
DC braking
(Braking response mode)
0: Slow response
1: Quick response
STOP key priority/
Start check function
0: STOP key priority disable/ Start check function disable
1: STOP key priority enable/ Start check function disable
2: STOP key priority disable/ Start check function enable
3: STOP key priority enable/ Start check function enable
0: Disable
1: Clear alarm data (Automatically return to 0 after clearing data)
Protection/Maintenance
function
(Operation selection)
0 to 255 (Data is displayed in decimal)
0: Disable; 1: Enable)
Bit 0: Lower the carrier frequency automatically (0: Disable; 1: Enable)
Bit 1: Input phase loss protection (0: Disable; 1: Enable)
Bit 2: Output phase loss protection (0: Disable; 1: Enable)
Bit 3: DC link bus capacitor life judgment selection
(0: Factory default referenced; 1: User measurement value standard)
Bit 4: Judge the life of DC link bus capacitor (0: Disable; 1: Enable)
Bit 5: Detect DC fan lock (0: Enable; 1: Disable)
Bit 6: Braking transistor error detection (0: Disable; 1: Enable)
Bit 7: IP20/IP40 switching (0: IP20 ; 1: IP40)
Password function password
2
Setting/comparison
0000 to FFFF (in hexadecimal)
*9: This is a function code for adjustment by the manufacturer. Do not access these function codes.
*15: When the sensorless vector control for PM is set to less than 10% of F04 (base frequency), the internal operation of H64 is limited to the P89
setting (%) of F04.
*16: Up to FRN0288G2S-2G/FRN0180G2-4G: 83 (decimal display) FRN0346G2S-2G/FRN0216G2-4G: 19 (decimal display)