EasyManua.ls Logo

Fuji Electric FRENIC MEGA G2 Series - Page 222

Fuji Electric FRENIC MEGA G2 Series
970 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5.2 Function Code Tables
5-38
Function
code
Name
Control method and Data setting range
Change when running
Data copying
Factory
default
Related page
d71
Master follower control
(Main speed regulator gain)
0.00 to 1.50 times
Y
Y
1.00
5-309
d72
(APR gain)
0.00 to 200.00 times
Y
Y
15.00
d73
(APR output +side limiter)
20 to 200 %: Limiter level
999: Disable
Y
Y
999
d74
(APR output -side limiter)
20 to 200 %: Limiter level
999: Disable
Y
Y
999
d75
(Z phase alignment gain)
0.00 to 10.00 times
Y
Y
1.00
d76
(Offset angle between
master and follower)
0 to 359 deg.
Y
Y
0
d77
(Synchronous completion
detection angle)
0 to 359 deg.
Y
Y
15
d78
(Deviation overflow
detection width)
0 to 65535 (10 pulse units)
Y
Y
65535
d79
For adjustment by
manufacturer *9
0, 80 to 240 (200 V series), 160 to 500 (400 V series), 999
N
Y2
999
5-336
d80
Motor 1 (Synchronous motor
magnetic pole position
draw-in frequency)
0.1 to 10.0 Hz
Y
Y
1.0
5-336
d81
For adjustment by
manufacturer *9
0 to 1
Y
Y
1
5-336
d82
Magnetic flux weakening
control
0: Disable
1: Enable
Y
Y
1
5-336
d83
Magnetic flux weakening
lower limit value
10 to 70 %
Y
Y
40
d84
For adjustment by
manufacturer *9
0 to 20
Y
Y
5
5-336
d85
For adjustment by
manufacturer *9
0 to 200
Y
Y
95
d86
Acceleration/deceleration
output filter
0.000 to 5.000 s
Y
Y
0.000
5-336
d88
For adjustment by
manufacturer *9
0.00 to 10.00, 999
Y
Y
999
5-336
d89
Motor 1
(Synchronous motor high-
efficiency control)
0 to 1
N
Y
1
5-336
d90
Magnetic flux level during
deceleration
100 to 300 %
Y
Y
120
5-336
d91
For special adjustment
0.00 to 2.00, 999
Y
Y
999
5-336
d92
For special adjustment
0, 0.01 to 3.00
Y
Y
0.00
5-336
d93
For adjustment by
manufacturer *9
0.00 to 10.00, 999
Y
Y
999
5-336
d94
For adjustment by
manufacturer *9
0.00 to 10.00, 999
Y
Y
999
d95
For adjustment by
manufacturer *9
0.00 to 10.00, 999
Y
Y
999
d96
For adjustment by
manufacturer *9
-50.0 to 50.0, 999
Y
Y
999
d97
For adjustment by
manufacturer *9
-50.0 to 50.0, 999
Y
Y
999
d98
For special adjustment
0 to 65535
Y
Y
0
5-336
d99
Extension function 1
0000 to FFFF (Display in hexadecimal)
Bit 0: For adjustment by manufacturer *9
Bit 1: For adjustment by manufacturer *9
Bit 2: For adjustment by manufacturer *9
Bit 3: JOG operation from communication (0: Disable; 1: Enable)
Bit 4: For adjustment by manufacturer *9
Bit 5, 6, 7: Not used
Bit 8: For adjustment by manufacturer *9
Bit 9: For adjustment by manufacturer *9
Bit 10: H30 definition switching
Y
Y
0000
5-337
d120
Brake signal (Brake-release
current) (REV)
0.00 to 300.00 %, 999:depends on the setting value of J68
Y
Y
999
5-337
d121
Brake control signal (Brake-
release frequency/speed)
(REV)
0.0 to 25.0 Hz, 999:depends on the setting value of J69
Y
Y
999
d122
Brake control signal (Brake-
release timer) (REV)
0.0 to 5.000 s, 999:depends on the setting value of J70
Y
Y
999
d123
Brake signal (Brake-release
torque) (REV)
0.00 to 300.00 %, 999:depends on the setting value of J95
Y
Y
999
d124
Brake control signal (Brake-
apply frequency/speed)
(REV)
0.0 to 25.0 Hz, 999:depends on the setting value of J71
Y
Y
999

Table of Contents