5.3 Description of Function Codes 5.3.1 F codes (Fundamental functions)
5-113
FUNCTION CODES
Chap 5
FUNCTION
CODES
F Codes
E Codes
C Codes
P Codes
H Codes
A Codes
b Codes
r Codes
J Codes
d Codes
U Codes
y Codes
K Codes
F31, F61
data
Subject of monitoring
Content
Definition of monitor amount
100 %
21
PG feedback value
Actual speed (When PG interface
option card is mounted, the speed
is always calculated and output
regardless of the control method.)
Maximum speed as 100 %
Bipolar output possible at
reverse side minus
22
Torque current
command
Torque current command (bipolar)
under vector control with speed
sensor, speed sensorless vector
control
Twice the motor rated torque
current
Bipolar output possible
23
PID deviation
PID command and PID feedback
value deviation
PID command 100%
Bipolar output possible
24
Reference line speed
Line speed setting
Maximum line speed 100%
Bipolar output possible
25
Winding diameter ratio
calculation value
Current winding diameter ratio
corresponding to minimum winding
diameter (d163)
d166: winding diameter
calculation (FM output gain)
sets how many times winding
diameter ratio equals monitor
amount of 100%
(10 V/20 mA/255, etc.)
(when d166 = 20, monitor
amount of 100% is 20 times
winding diameter ratio)
26
Setting frequency
(before
acceleration/decelerati
on calculation)
Setting frequency immediately
before acceleration/deceleration
arithmetic unit
Maximum frequency 100%
Bipolar output possible
111
Customizable logic
output signal 1
Enable only at analog output
±100%
Bipolar output possible
112
Customizable logic
output signal 2
Enable only at analog output
±100%
Bipolar output possible
113
Customizable logic
output signal 3
Enable only at analog output
±100%
Bipolar output possible
114
Customizable logic
output signal 4
Enable only at analog output
±100%
Bipolar output possible
115
Customizable logic
output signal 5
Enable only at analog output
±100%
Bipolar output possible
116
Customizable logic
output signal 6
Enable only at analog output
±100%
Bipolar output possible
117
Customizable logic
output signal 7
Enable only at analog output
±100%
Bipolar output possible
118
Customizable logic
output signal 8
Enable only at analog output
±100%
Bipolar output possible
119
Customizable logic
output signal 9
Enable only at analog output
±100%
Bipolar output possible
120
Customizable logic
output signal 10
Enable only at analog output
±100%
Bipolar output possible
121
Customizable logic
output signal 11
Enable only at analog output
±100%
Bipolar output possible
122
Customizable logic
output signal 12
Enable only at analog output
±100%
Bipolar output possible
123
Customizable logic
output signal 13
Enable only at analog output
±100%
Bipolar output possible

Table of Contents