EasyManua.ls Logo

Fuji Electric FRENIC MEGA G2 Series - Page 575

Fuji Electric FRENIC MEGA G2 Series
970 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5.3 Description of Function Codes 5.3.10 U codes (Customizable logic operation)
5-391
FUNCTION
CODES
F Codes
E Codes
C Codes
P Codes
H Codes
A Codes
b Codes
r Codes
J Codes
d Codes
U Codes
y Codes
K Codes
FUNCTION CODES
Chap 5
The block diagrams for each operation circuit are given below. The setting value for functions 1 and 2 is indicated
with U04 and U05
(2001) Adder (2002) Subtracter (2003) Multiplier
Output
Input 1
Input 2
+
+
U04
U05
Output
Input 1
Input 2
-
+
U04
U05
Output
Input 1
Input 2
U04
U05
×
(2004) Divider (2005) Limiter (2006) Absolute value of inputs
Output
Input 1
Input 2
U04
U05
÷
Output
Input 1
Input 2
U04
U05
Output
Input 1
Input 2
Absolute
value
Operation
U04
U05
(2007) Inverting adder (2008) Variable limiter (2009) Linear function
Output
Input 1
Input 2
+
U04 -1
×
U05
+
+
(2010) Remainder (2051) Comparator 1 (2052) Comparator 2
󲷐
󲷑
U04
U05
剰余
Output
Input 1
Input 2
With Input 1-Input 2 U04+|U05|
Output ON
With Input 1-Input 2 U04-|U05|
Output OFF
Output
Input 1
Input 2
With Input 1-Input 2 > U04+|U05|
Output ON
With Input 1-Input 2 < U04-|U05|
Output OFF
ON is prioritized when both conditions
are satisfied.
(2053) Comparator 3 (2054) Comparator 4 (2055) Comparator 5
Output
Input 1
Input 2
|With Input 1-Input 2| U04+|U05|
Output ON
|With Input 1-Input 2| ≤ U04-|U05|
Output OFF
Output
Input 1
Output ON when Input 1 ≥ U04
Output OFF when Input 1 < U04 |U05|
U04
ON is prioritized when both conditions are satisfied.
Input 1
Out
In
1
In
2
KA×入力1+KB
U04 U05
Input 1
Input 2
|With Input 1-Input 2| > U04+|U05|
Output ON
Output
|With Input 1-Input 2| < U04-|U05|
Output OFF
󲷐
󲷑
S001
U04
Input 1
Input 2
Output
Output
Input 1
Input 2
Remainder

Table of Contents