5.3 Description of Function Codes 5.3.10 U codes (Customizable logic operation)
(2056) Comparator 6 (2057) Comparator 7 (2058) Comparator 8
Output
Input 1
With Input 1 ≤ U04
Output ON
With Input 1 > U04+|U05|
Output OFF
U04
1
2
1-2U04+|U05|ON
1-2U04-|U05|OFF
出力
入力1
入力2
|入力1-入力2|>U04+|U05|:ON
|入力1-入力2|U04-|U05|:OFF
(2059) Equivalent comparator 2 (2071) Window comparator 1 (2072) Window comparator 2
Out
In
1
In
2
|In1-In2||U05|:ON
|In1-In2|>|U05|:OFF
Output
Input 1
Input 2
With U04 ≥ Input 1 ≥ U05
Output ON
With Input 1 > U04, Input 1 < U05
Output OFF
U05
U04
Output
Input 1
Input 2
With U04 > Input 1 > U05
Output ON
With Input 1 ≥ U04, U05 ≥ Input 1
Output OFF
U05
U04
(2101) High selector (2102) Low selector (2103) Average of inputs
(2151) Function code input (2201) Scale inverse converter (2202) Scale converter
Output
Input 1
Input 2
S13
0% 100%
U04
U05
Output
Input 1
Input 2
U05 U04
100.00
0
* Use this to connect to analog
output terminals.
* Up to 2 steps can be used.
* The input 1 signal selection
can only be used for setting
value 8000 to 8085.
* Up to 2 steps can be used.
(3001) Quadratic function (3002) Square root function
Output
Input 1
Input 2
U04
U05
CB
2
A
K1 InputK1 InputK ++
Output
Input 1
Input 2
U04
U05
* Either (3001) or (3002) is available to use, and only one of these functions can be used.
Input 1 output
when Input 1 ≥ Input 2
Input 2 output
when Input 1 < Input 2
Input 1 output
when Input 1 ≤ Input 2
Input 2 output
when Input 1 > Input 2
(Input 1 + Input 2) / 2 output