11.22 Built-in Option Card Types and Ports in Which They Can be Installed
11-86
11.22 Built-in Option Card Types and Ports in Which They Can be Installed
The FRENIC-MEGA option card connection ports in which each built-in option card can be installed are shown in
the following table.
Table 11.22-1
Class
Type
Option card
connection port
Remarks
A port
B port
C port
Relay output
OPC-RY
Y
Y
N
Two cards can be installed simultaneously in the A and B ports
(4 outputs).
Feedback
OPC-PG
N
N
Y
OPC-PG2
N
N
Y
OPC-PG22
N
*1
Y
OPC-PMPG2
N
*1
Y
Dedicated MEGA part for driving synchronous motors
I/O system
OPC-DI
Y
Y
Y
A single card (A, B, or C) can be installed.
OPC-DO
Y
Y
Y
A single card (A, B, or C) can be installed.
OPC-AIO
Y
Y
Y
A single card (A, B, or C) can be installed.
Communica
tion system
OPC-DEV
Y
Y
Y
Only one communication system option can be installed
(example: OPC-DEV and OPC-TL cannot be used at the
same time.)
OPC-TL
Y
N
N
OPC-COP2
Y
N
N
OPC-PDP2
Y
N
N
OPC-CCL
Y
N
N
OPC-SX
Y
N
N
OPC-ETM
Y
N
N
Compatible with ROM version 0300 and later
*1 The B/C port area is occupied, and therefore other options cannot be installed in the B port.
Fig. 11.22-1
When using an IP40 compatibility attachment, only a single option card can be installed. (Two OPC-RY
relay output interface cards can be installed.)
C port
B port
A port
Control terminal
block
CN6
CN5