11.22 Built-in Option Card Types and Ports in Which They Can be Installed
11-103
SELECTING PERIPHERAL EQUIPMENT
Chap 11
Table11.22-19 Function code types
Type
Type code
Name
Type
Type code
Name
Type
Type code
Name
S
2
02h
Command, function
data
W
16
10h
Monitor data 2
T
30
1Eh
Scheduled operation
M
3
03h
Monitor data
X
17
11h
Alarm data
E1
31
1Fh
Terminal function
F
4
04h
Basic function
z
18
12h
Alarm data 2
H1
32
20h
High performance
function
E
5
05h
Terminal function
b
19
13h
Motor 3/speed control 3
parameter
o1
33
21h
Option function
C
6
06h
Control function
d
20
14h
Application function 2
U1
34
22h
Customizable logic
function
P
7
07h
Motor 1 parameter
-
M1
35
23h
Monitor data
H
8
08h
High performance
function
-
J1
36
24h
Application function
A
9
09h
Motor 2/speed control
2 parameter
W1
23
17h
Monitor data 2
J2
37
25h
Application function
o
10
0Ah
Option function
W2
24
18h
Monitor data 2
J3
38
26h
Application function
L
11
0Bh
Special function
W3
25
19h
Monitor data 2
J4
39
27h
Application function
r
12
0Ch
Motor 4/speed control
4 parameter
X1
26
1Ah
Alarm data
J5
40
28h
Application function
U
13
0Dh
Customizable logic
function
X2
27
1Bh
Alarm data
J6
41
29h
Application function
J
14
0Eh
Application function
Z1
28
1Ch
Alarm data 2
d1
42
2Ah
Application function 2
y
15
0Fh
Link function
K
29
1Dh
Keypad related
functions
d2
55
37h
Application function 2
Example: In the case of F26
F type code 04
"041A"
26 1A(hexadecimal notation)
Communication formats
Supported communication formats are shown in the following table. Select o31 for output, and o32 for input. Please
be aware that changes to the o31 and o32 settings are not reflected until the inverter power is turned OFF and ON
again.
Table 11.22-20 Format list
o31, o32
Type
Instance ID
Content
Occupied
words
o31 = 20
Output
(master → inverter)
20
Basic I/O instance output
4
o31 = 21 or 0
(initial value)
21
Extension I/O instance output
4
o31 = 100
100
Fuji Electric original output
4
o31 = 102
102
Data mapped I/O (write)
8
o31 = 104 *
104
Function code access request
8
o32 = 70
Input
(inverter → master)
70
Basic I/O instance input
4
o32 = 71 or 0
(initial value)
71
Extension I/O instance input
4
o32 = 101
101
Fuji Electric original input
4
o32 = 103
103
Data mapped I/O (monitor)
8
o32 = 105 *
105
Function code access response
8
* When selecting function code access request (o31 = 104) for the output format, select the function code access
response (o32 = 105) for the input format. Refer to the DeviceNet Communication Card Instruction Manual for
details.

Table of Contents