11.22 Built-in Option Card Types and Ports in Which They Can be Installed
11-103
SELECTING PERIPHERAL EQUIPMENT
Table11.22-19 Function code types
High performance
function
Motor 3/speed control 3
parameter
Customizable logic
function
High performance
function
Motor 2/speed control
2 parameter
Motor 4/speed control
4 parameter
Customizable logic
function
Example: In the case of F26
26 1A(hexadecimal notation)
Communication formats
Supported communication formats are shown in the following table. Select o31 for output, and o32 for input. Please
be aware that changes to the o31 and o32 settings are not reflected until the inverter power is turned OFF and ON
again.
Table 11.22-20 Format list
Output
(master → inverter)
Basic I/O instance output
o31 = 21 or 0
(initial value)
Extension I/O instance output
Fuji Electric original output
Function code access request
Input
(inverter → master)
o32 = 71 or 0
(initial value)
Extension I/O instance input
Fuji Electric original input
Data mapped I/O (monitor)
Function code access response
* When selecting function code access request (o31 = 104) for the output format, select the function code access
response (o32 = 105) for the input format. Refer to the DeviceNet Communication Card Instruction Manual for
details.