11.22 Built-in Option Card Types and Ports in Which They Can be Installed
11-108
Function
code
Description
Factory
default
Setting
o221
to
o252
Write function code
assignment 1 to 32
(max. 32 words)
Set function code for writing output from master to inverter.
(Group number) × 100
H
+ 2 lower order digits of function
code (see inverter function code settings)
Example: Function code E01 = 0501
H
(hexadecimal
number)
o253
to
o284
Read function code
assignment 1 to 32
(max. 32 words)
Set function code for reading input from inverter to master.
(Group number) × 100
H
+ 2 lower order digits of function
code (see inverter function code settings)
Example: Function code E01 = 0501
H
(hexadecimal
number)
Inverter function code settings
If accessing inverter function codes, specify the function code type (Table 11.22-24) and number with a 4 digit
hexadecimal number as follows.
However, these are ignored if the inverter has no function codes.
機能コード番号(16進表記)
機能コード種別(付録表1.1による)
Table 11.22-24 Function code type
Type
Type code
Function code name
Type
Type code
Function code name
S
2
02
H
Command, function data
W3
25
19
H
Monitor data 2
M
3
03
H
Monitor data
X1
26
1A
H
Alarm data
F
4
04
H
Basic function
X2
27
1B
H
Reserved
E
5
05
H
Terminal function
Z1
28
1C
H
Reserved
C
6
06
H
Control function
K
29
1D
H
Keypad related function
P
7
07
H
Motor 1 parameter
T
30
1E
H
Scheduled operation
H
8
08
H
High-level function
E1
31
1F
H
Reserved
A
9
09
H
Motor 2/speed control 2 parameter
H1
32
20
H
High-level function
o
10
0A
H
Option function
o1
33
21
H
Option function
L
11
0B
H
Specific purpose function
U1
34
22
H
Customizable logic function
r
12
0C
H
Motor 4/speed control 4 parameter
M1
35
23
H
Monitor data
U
13
0D
H
Customizable logic function
J1
36
24
H
Application function
J
14
0E
H
Application function
J2
37
25
H
Application function
y
15
0F
H
Link function
J3
38
26
H
Application function
W
16
10
H
Monitor data 2
J4
39
27
H
Application function
X
17
11
H
Alarm data
J5
40
28
H
Application function
Z
18
12
H
Alarm data 2
J6
41
29
H
Application function
b
19
13
H
Motor 3/speed control 3 parameter
d1
42
2A
H
Application function 2
d
20
14
H
Application function 2
d2
55
37
H
Application function 2
W1
23
17
H
Monitor data 2
o2
62
3E
H
Option function
W2
24
18
H
Monitor data 2
Example: In the case of F26
F → type code 04
"041A"
26 → 1A (hexadecimal notation)
Based on function code type (Table 11.22-24)